Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsLoad Break Switch

Indoor / Outdoor Load Compact Switches , Electric 3P 4P Load Disconnect

Indoor / Outdoor Load Compact Switches , Electric 3P 4P Load Disconnect

    • Indoor / Outdoor Load Compact Switches , Electric 3P 4P Load Disconnect
    • Indoor / Outdoor Load Compact Switches , Electric 3P 4P Load Disconnect
    • Indoor / Outdoor Load Compact Switches , Electric 3P 4P Load Disconnect
  • Indoor / Outdoor Load Compact Switches , Electric 3P 4P Load Disconnect

    Product Details:

    Place of Origin: YUEQING , ZHEJIANG , CHINA
    Brand Name: GRL
    Certification: CE , CCC
    Model Number: HGL

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: Consultation
    Packaging Details: Standard carton packaging
    Delivery Time: 20 days after payment
    Payment Terms: T/T, Western Union
    Supply Ability: 100000 PCS Per Month
    Detailed Product Description
    Prodcut Name: Load Break Switch Max Voltage: 660V
    Max Current: 3150A Material: Pa66 Or DMC
    Grade: Flame Retardant Grade V0 Contact Material: Copper T3
    Plated: Tinned Plated Standard: IEC60947-3 And GB14048.3

    CE approved 3 poles Copper T3 Load Electrical Isolator DIsconnector Switch

     

    Introduction

     

    HGL Series Load Break Switch:
    1, the load circuit breaker can be loaded with the self-extinguishing function. Disconnector generally can not load broken, the structure is not on the arc cover, can be separated from the load isolation switch, but the structure and load switch is different, relatively simple.
    2, load the circuit breaker and disconnector, can form a clear point, most of the circuit breaker is not isolated function, there are several circuit isolation equipment isolation.
    3, the load circuit breaker does not protect the function, the load switch with overload protection.
    4, the load circuit breaker and fuse combination of electrical appliances can automatically trip, with some of the functions of the circuit breaker.
    Circuit breakers can have short circuit protection, overload protection, leakage protection and other functions.

     

    Parameters

     

    Conventional current 160A 250A 630A 1600A 3150A
    Rated current In(A) 160 250 315 400 500 630 1000 1250 1600 2000
    Rated insulation voltage Ui (V) 690 1000
    Motor power 380V 80 132 160 220 280 315 560 560 560 710
    P(Kw) 660V 75 110 185 185 185 185 475 475 475 750
    Rated short-time withstand current lcw (kA Rms) 0.1s/1s 8 12 25 25 25 25 50 50 50 50
    Rated breaking capability Icn (A Rms) AC23 380 V 1000 1600 2520 3200 4000 5040 3000 3750 4800 6000
    Rated making capability Icm (A Rms)AC23 380V 1600 2500 3150 4000 5000 6300 3000 3750 4800 6000
    Rated shortcurrent making capabilityIcm 13.6 17 40 40 40 40 70 70 70 105
    (kA peak value)
    Mechanical durability 380V 1400 1400 800 800 800 800 500 500 500 300
    Electical curability 380V 200 200 200 200 200 200 100 100 100 100
    Operation moment (Nm) 6.5 10 14.5 14.5 14.5 14.5 37 37 60 60
    Weight (kg) 3 poles 1.3 2.2 4.3 4.3 4.7 4.7 10.5 10.5 16 25.5
    4 poles 1.5 2.6 5.4 5.4 6 6 13 13 20 37.5

     